Circuit ID - How Labeling Works

Circuit ID - How Labeling Works

Reference: http://en.wikipedia.org/wiki/Circuit_ID

Telecom Circuit ID formats

The LEC circuit IDs are based on Telcordia Technologies' Common Language Coding. At one time, the abbreviations were meaningful (for example, HC for high capacity) but the complexity of the business no longer allows for it.

Carrier Facility format: AAAAA/BBBBBB/CCCCCCCCCCC/DDDDDDDDDDD[1]

  • A Prefix: 3-5 Alphanumeric characters. Required.
  • B Facility Type: 2–6 Alphanumeric characters. Required.
  • C A CLLI Code: 8 or 11 alphanumeric characters. This is a Required Field.
  • D Z CLLI Code: 8 or 11 alphanumeric characters. This is a Required Field.

Example:

  • HN101/T3U/MPLSMNDT000/GLVYMNORIII is an unframed T3 circuit between two locations in Minnesota.

Serial Number format: AA/BBCC/DDDDDD/EEE/FF/G prefix/service code - service code modifier/serial number/suffix/company identifier/segment name





  • A Prefix: 1–2 alphanumeric characters. Optional. They may or may not be based on LATA
  • B Service Code: 2 Characters. Required. The type of service this circuit is providing.
  • C Service Code Modifier: 2 Characters. Required. Modifies the service code, often used for different billing options.
  • D Serial Number: 1–6 digits. Required.
  • E Suffix: 3 character suffix to the serial number. May be required, but rarely used.
  • F Company Code: 2–4 alphabetic characters (NW, MS, PN, GTEW, NRLD, UDMN, FROT) Required, identifies the Controlling LEC.
  • G Segment: 1–3 alphanumeric characters. Optional for point to point, but usually found with multi-point DS0 circuits.

Example:

  • 32/HFGS/012345/NW is a T3 Circuit by Qwest
  • 73/HCGS/123456/000/NE is a T1 Circuit by New England Telephone
  • 44/AQDU/987654/000/G4 is a HDSL Circuit by G4 Telecom

Telephone Number Format: AA/BBBB/CCC/DDD/EEEE/FF/G

  • A Prefix: Alphanumeric characters. Required if it exists.
  • B Service Code & Modifier: 2–4 alphabetic characters. Required for non-DSL numbered circuits.
  • C NPA: 3 digits. This is a required field.
  • D NXX: 3 digits. This is a required field.
  • E Line: 4 digits. This is a required field.
  • ? Extension: 1–5 alphanumeric characters. This is an optional field.
  • F For states: AZ, CO, ID, MT, NM, UT, WY, alphas not accepted; convert D1 to 0001, D2 to 0002, etc.
  • G Segment: 1–3 alphanumeric characters. This is an rarely used optional field.


Click to expand
Circuit IDs

 

* Please use the comment form below. Comments are moderated.*



Related Posts

 

Comments

No comments made yet. Be the first to submit a comment
Monday, 23 December 2024